POCT
FreeStyle Libre Reader & Sensor
Brand - Abbott
Model –FreeStyle Libre Reader & Sensor
Features
- Get glucose readings with a painless one-second scan. FreeStyle Libre Reader can capture data from within 1cm to 4cm of the Sensor, even through clothing Using the supplied disposable applicator, FreeStyle Libre Sensor can be easily applied and stays on the back of your upper arm for upto 14 days
- The Reader stores 90 days of glucose data, so you can see a complete picture of your glucose levels over 3 months
- The Sensor automatically measures and continuously stores glucose readings day and night FreeStyle Libre is designed to be water-resistant and can be worn while bathing, showering, swimming and exercising. The Sensor is water resistant up to 1 meter (3feet). Do not immerse longer than 30 minutes. Sensor works for 14 days. For repeat usage re-order the Sensor.
Get in Touch
Afinion™ 2
Brand - Abbott
Model –AFINION 2
Features
- Multiple analytes on one instrument
- All-in-one test cartridge
- Automatic self-check system
- No additional calibration necessary
Specification
- Four tests on one platform; HbA1c, Lipid Panel, ACR, CRP
- Easy handling steps
- Size: 20 cm x 19 cm x 33 cm
- Weight: 3.4 kg
- Color touch display
- USB connection for optional barcode reader and printer
- Connectivity solutions that support POCT1-A
- QC and operator lockout
- No maintenance needed
- No calibration needed
- Unique integrated failsafe system
Get in Touch
UroMeter 120
Brand - Abbott
Model –UroMeter 120
URINE CHEMISTRY ANALYZER
Features
- Auto calibration after startup
- Simple connectivity via USB communication port
- Ergonomic design enhances user convenience even for left-handed users
- Enhance work efficiency by easily switching between quick mode and normal mode
- Easy to input multiple IDs by keyboard, PC and barcode reader
- Easily switch to your language by
- user-defined method
- 4 ~ 11 parameter testing available
- Maximum 300 tests/hour, average 120 tests/hour
- Easy to learn and operate
Specification
- Power Adapter: DC 12V 3.33A (100–240V, 50/60 Hz)
- Size: 252 × 200 × 114 mm (W × D × H)
- Weight: 1.2 kg (2.65 lb)
- Memory: 100,000 results
- Print: Internal thermal printer
- LCD: 320*240 QVGA color
- RS232C Interface:
– COM1: Communication with PC
– COM2: Communication with barcode system
Get in Touch
UroMeter 720
Brand - Abbott
Model –UroMeter 720
Features
- High capacity — maximum 720 tests per hour
- Easy to input ID and use data
- Easy to input multiple IDs by keyboard, PC and barcode reader
- Maximum 100,000 test results memory
- Easy software version upgrade (drag and drop PC to UroMeter 720, no memory replacement)
- Easily switch to your language by user-defined method
- Easy to set up and maintain
- 4 ~ 11 parameter testing available
Specification
- Power Adapter: DC 12V 3.33A (100–240V, 50/60 Hz)
- Size: 320 × 260 × 178 mm (W × D × H)
- Weight: 2.4 kg (5.3 lb)
- Memory: 100,000 results
- Print: Internal thermal printer
- LCD: 320*240 QVGA color
RS232C Interface:
– COM1: Communication with PC
– COM2: Communication with barcode system
Get in Touch
Panbio™ Dengue Early ELISA
Brand - Abbott
Model –Panbio™ Dengue Early ELISA
Features
- Easy to use
- The test uses a single dilution of serum.
- Cost effective
- Break-apart wells and ready-to-use colorcoded reagents are compatible with standard microplate technology.
- Fast Results
- The total incubation time for the Dengue Early ELISA is 2 hr 10 min.
- Flexible
- For use in endemic and non-endemic areas.
- Early
- NS1 antigen circulates at detectable levels from the first day after the onset of symptoms up to Day 9. NS1 circulates at high levels in the sera of patients experiencing primary as well as secondary infections during the entire clinical phase of illness.
- Helpful Documents
Specification
- Sensitivity
- Study in Vietnam : 146/188 (77.7%)
- Study in Thailand : 57/75 (76.0%)
- Specificity
- Study in Vietnam : 44/47 (93.6%)
- Study in Thailand : 179/182 (98.4%)
Get in Touch
Panbio™ Leptospira IgM ELISA
Brand - Abbott
Model –Panbio™ Leptospira IgM ELISA
Features
- Fast Results
- Within 1 hr 10 min.
- Easy to Use
- Standardised Indirect ELISA procedure.
- Time Efficient IgM
- No need to incubate RF absorbent and serum prior to addition to antigen-coated wells.
- Cost Effective
- Incorporates break apart wells.
- High Sensitivity
- Detects IgM antibodies to a broad range of serovars.
Specification
- Sensitivity: 96.5% (55/57)
- Specificity: 98.5% (192/195)
Get in Touch
SD BIOLINE TB Ag MPT64 Rapid
Brand - Abbott
Model –SD BIOLINE TB Ag MPT64 Rapid
Features
- Rapid discrimination between the M. tuberculosis complex and MOTT bacilli
- Identification of the M. tuberculosis complex in combination with culture systems
- Sample: Colony, Condensation fluid(Solid cultures) or Liquid cultures
Get in Touch
Determine™ HBsAg 2
Brand - Abbott
Model –Determine™ HBsAg 2
Features
- Increase case finding
- Detecting infection earlier leads to better patient outcomes
- Rapid turnaround time helps reduce patients lost to follow up
- Simple procedure with no special expertise or lab equipment required
- Flexibility of multiple sample types
- Detects major HBsAg mutants (refer to Product Insert)
- Ideal for use in a wide variety of healthcare settings
Specification
- Analytical sensitivity: 0.1 IU/mL
- Specificity: 99.6%
- Sample volume: 50µl
- Time to result: 15 min
- Sample types: Serum/Plasma, Fingerstick Whole Blood, Venipuncture Whole Blood
- Detect major vaccine escape mutants (refer to Product Insert)
- Shelf life: 18 months
- Storage conditions: 2-30°C
- 20 tests or 100 tests format
Get in Touch
Determine™ HIV Early Detect
Brand - Abbott
Model –Determine™ HIV Early Detect
Features
- Detects more acute infections
- Helps increase case finding
- Facilitates fast linkage into appropriate care
- Robust to major circulating subtypes
- Rapid, accurate result in just 20 minutes
- Easy to use – requires minimal training and no expensive lab equipment
Specification
- Analytical sensitivity: 0.1 IU/mL
- Specificity: 99.6%
- Sample volume: 50µl
- Time to result: 15 min
- Sample types: Serum/Plasma, Fingerstick Whole Blood, Venipuncture Whole Blood
- Detect major vaccine escape mutants (refer to Product Insert)
- Shelf life: 18 months
- Storage conditions: 2-30°C
- 20 tests or 100 tests format
Get in Touch
Determine™ HIV-1/2
Brand - Abbott
Model –Determine™ HIV-1/2
Features
- Fast
- Determine™ HIV-1/2 yields clear, dependable results in 15 minutes.
- Easy to Use
- Simple, minimal steps to maximize testing efficiency.
- Flexible
- Can be used with serum, plasma, or whole blood.
Specification
- HIV-1 Positive 100%
- HIV-2 Positive 100%
- HIV-1 Subtype A-G 100%
- HIV-1 Group O 100%
- Europe 100%
- North America 100%
- Asia 100%
- Africa 99.91%
- Specificity
- Overall 99.75%
- Product Information
- Method: Lateral flow
- Time to results: 15 minutes
- Storage conditions: 2-30°C (36-86°F)
- Shelf-life: 18 months
- Sample types: Serum/Plasma/Whole blood
Get in Touch
Bioline™ Malaria Ag P.f/Pan
Brand - Abbott
Model –Bioline™ Malaria Ag P.f/Pan
Features
- Distinguish f infection from other species (P.v, P.m or P.o)
- Useful in regions where all malaria species are circulating
- WHO prequalified
- Specimen : Whole blood (5 μl)
- Time to result : 15 minutes (up to 30 minutes)
- 1-40°C for 24 months
Specification
- Performance:
– P.f (HRP2) : Sensitivity 99.7 %, Specificity 99.5 %
– Pan (pLDH) : Sensitivity 95.5 %, Specificity 99.5 %
Get in Touch
Bioline™ Malaria Ag P.f/P.v
Brand - Abbott
Model –Bioline™ Malaria Ag P.f/P.v
Features
- Differential diagnosis between Plasmodium falciparum and
Plasmodium vivax - Useful for the region where P.v and P.f are both dominant
- Differentiate P.f mono infection from P.f/P.v co-infection
- WHO prequalified
- Specimen : Whole blood (5 μl)
- Time to result : 15 minutes (up to 30 minutes)
- 1-40°C for 24 months
Specification
- Performance:
- f (HRP2) : Sensitivity 99.7 %, Specificity 99.5%
- v (pLDH) : Sensitivity 95.5 %, Specificity 99.5%
Get in Touch
Panbio™ Dengue Early Rapid
Brand - Abbott
Model –Panbio™ Dengue Early Rapid
Features
- NS1 antigen can be detected in serum from day 1 after onset of fever and up to day 91,2,3. This compares to IgM antibodies that are not detectable until days 4-54,5 .
- The new device format for dengue NS1 detection performed better, is easy to use and interpret compared to the strip format.
Specification
- Sensitivity: 91.89% (102/111)
- Specificity: 98.39% (183/186)
Get in Touch
Bioline™ Dengue Duo (Dengue NS1 Ag + IgG/IgM)
Brand - Abbott
Model –Bioline™ Dengue Duo (Dengue NS1 Ag + IgG/IgM)
Features
- Simultaneous detection of Dengue Ag & Ab
- Cover all clinical stages from acute phase to convalescence phase of infection
- Fast test result : 15~20 min
- Convenient storage condition : 1~30°C
Specification
- Performance
– Sensitivity : 92.4% (Dengue NS1 Ag), 94.2% (Dengue IgG/IgM)
– Specificity : 98.4%(Dengue NS1 Ag), 96.4% (Dengue IgG/IgM)
Get in Touch
Hemocue Hb 201+ System
Brand - Abbott
Model –Hemocue Hb 201+ System
Features
- Principle : Modified azidemethemoglobin reaction; dual wavelengths (570 nm and 880 nm) for compensation of turbidity
- Calibration : Factory calibrated against the ICSH reference method; needs no further calibration.
- Measurement Range : 0–25.6 g/dL (0–256 g/L, 0–15.9 mmol/L)
- Results : Within 60 seconds.
- Sample Volume : ~10 μL
Get in Touch
Hemocue Hb 301 System
Brand - Abbott
Model –Hemocue Hb 301 System
Features
- Principle : Absorbance measurement of whole blood at an Hb/HbO2 isobestic point; dual wavelengths (506 nm and 880 nm)
- for Hb measurement and turbidity compensation
- Calibration : Factory calibrated against the ICSH reference method; needs no further calibration
- Sample Material : Capillary, venous or arterial whole blood
- Measurement Range : 0–25.6 g/dL (0–256 g/L, 0–15.9 mmol/L)
Results : ≤3 seconds
Sample Volume : ~10 μL