HBA1c, Thalasemia testing
D-10 Analyzer
Brand -Bioroad
Model –D-10 Analyzer
Features
- Complete ready to use reagent kit includes required buffers, Calibrators, Primers and Analytical cartridge.
- Offers NGSP and IFCC value reporting for the same patient.
- Sample Processing time- 3 Minutes for HbA1c and 6.5 Minutes for A2 (Thalassemia)
- 10 samples can be run at a time.
- Colored Calibrated peaks simplify the result review.
- Sampling from Primary whole blood tubes – No samples preparation.
- Low maintenance cost and time.
- Single calibration stability.
- Common hemoglobin variants appear in dedicated window.
- Simple change of mode for HbA1c to Thalassemia testing without any reagent change.
Get in Touch
Variant II Turbo
Brand -Bioroad
Model –Variant II / Variant II Turbo
Features
- High Throughput Analyzer with continues Loading of Samples.
- Complete ready to use reagent kit includes required buffers, Calibrators, Primers and Analytical cartridge.
- Offers NGSP and IFCC value reporting for the same patient.
- Result Time – 5 minutes for A2 and 97 Seconds for HbA1c.
- Variant II / Turbo kit has fewer – Reagent changes, System Calibrations, Maintenance Interactions and Cartridges Replacement.
- Sampling from Primary whole blood tubes – No samples preparation.
- Common hemoglobin variants appear in dedicated window.
- Colored Calibrated peaks simplify the result review.
- Single calibration stability.
Get in Touch
AutoDELFIA
Brand -PerkinElmer
Model –AutoDELFIA
AutoDELFIA is a fully automatic system for reproducible quantitation of analytes commonly used in prenatal screening programs.
Features
- Ability to run a complete range of prenatal assays
- User friendly instrument software
- Better design for improved instrument ergonomics
- FMF approved assays
- Comprehensive range of maternal fetal health assays
- New graphical user interface and operational modes for improved workflow management.
- One-glance overview of screening process
- Tracking of mandatory maintenance routine by new System Maintenance feature
- Automatic import of kit lot data using new 2D-barcoded AutoDELFIA kit QC certificates
- Improved safety and reliability – no manual work steps and minimal risk of user error
- Liquid samples in barcoded tubes
- Sample Capacity – Up to 432 patient tubes in 36 racks, 12 sample/rack Automatic sample dilution when Specified (dilution factors 1:5 – 1:100)
- Sample Processing – Carry Over < 0.01% Accuracy – Better than +/- 3% or +/- 1uL (whichever is greater) at 25 uL and larger volumes Precision – CV % < 3% for volumes > 25 uL
- Plate processing – Precision CV % of one plate with 1 nM Eu solution < 1%
Get in Touch
VICTOR2 D
Brand -PerkinElmer
Model –DELFIA EXPRESS
Semi Automated Prenatal Screening Instrument
Features
- Equipped with DELFIA Technology
- Ideal measurement instrument for different size laboratories
- Easy to use and reliable measurement device
- Right balance of cost-effectiveness and control
- Time-resolved fluorescence- DELFIA® assays (TSH, T4, 17-OHP, IRT)
- Detection Units – Fluorometry and TR-fluorometry
- Photomultiplier tube, R 1527
- Emission filter slide A, provided with eight filter positions (Ø 25.4 mm) with the following filters 405, 460, 486, 535, 590, 615 and 642 nm. Changeable emission filter slide B, provided with eight filter positions (Ø25.4 mm)
Get in Touch
Gazelle™ Hb Variant Test
Brand -Hemex Health
Model –Gazelle™ Hb Variant Test
Features
- Gazelle’s Microchip Electrophoresis
- Accurate Results Available At The Patient Visit
- Automated Interpretation
- Lightweight, Battery-Powered Reader Tested For Tropical Environments
- Digital Storage And Printing
- Principle – Electrophoresis
- Time to Result – 8 minutes
- Limitations – Hb A2/C/E comigrate. Hb A2 is quantified in combination with Hb C and Hb E. Hb A2 alone is below the limit of detection
- Data Storage – Reader stores over 2500 tests
Get in Touch
DELFIA EXPRESS
Brand -PerkinElmer
Model –DELFIA EXPRESS
Semi Automated Prenatal Screening Instrument
Features
- The speed and flexibility of random access
- The simplicity and ease of use of a new generation
- instrument with up-to-date software design
- The security associated with barcoded reagents and
- samples to ensure positive identification
- The reassurance from using reliable, proven DELFIA
- Chemistry
- Throughput 40 tests per hour
- Process time 30 minutes per test
- Kit capacity 96 tests or 72 tests
- Bulk reagents capacity 180 – 250 tests